<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15349</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Picker wrist cylinder is faulty
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Call Creo for assistance.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
If this error is reported, the picker wrist cylinder is probably faulty.
</text></DescriptionText>
<DescriptionText><text>
If there are problems during a pick, the firmware does extra steps to try and figure out
the real problem.  For this error to be reported, the picker will have tried to grab the
plate, but the wrist timed out moving out.  Even after releasing vacuum, the wrist still
wouldn't come out.  The picker head was moved out, then back in to try and re-seal the wrist
cylinder.  The wrist was then moved back in to grab the plate, then the wrsit was moved out.
Still the wrist wouldn't come out.  This could be a bad sensor, but the sensor is checked
before the wrist moves in the first time to grab the plate, and it had read TRUE at that time.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The wrist cylinder is leaking.
</Cause>
<Cause>
The wrist sensor may be intermittant.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_state_wle.xml</LinkAddress><LinkTitle>NVS: al wle</LinkTitle></Link>
<Link><LinkAddress>../error_messages/15319.xml</LinkAddress><LinkTitle>E_ALE_PLATES_STICKING_TOGETHER</LinkTitle></Link>
<Link><LinkAddress>../error_messages/15348.xml</LinkAddress><LinkTitle>E_ALE_BAD_WRIST_SENSOR</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:03 2008 PST
</Updated>
<Links>
</Links>
</Error>